Electric back sprayers  with a compact and flexible, easy to use, ergonomic advantages, more and more farmers and friends favorite to become the main tool for spraying. However, because many farmers friends did not master the correct way to use electric sprayer frequent cause various problems. So, electric sprayer out of trouble how to solve?

1, spraying handle switch at the water leakage. Switch asbestos gasket wear or abrasion may cause the switch switch leakage, this phenomenon occurs, it should be replaced with new washers or asbestos. The leak was due to skin damage or gasket sealing off the gas chamber, and therefore timely for welding.

2, do not play into the gas chamber, the electric joystick under pressure does not focus. This is because the hardening shrinkage or cracking spray cup, the cup bottom of the nut loosening caused. Cup should be little pressure to open or replace it with new cups, immersed in oil or lubricating oil, lubricating installed after expansion, coated with a little oil, and tighten the bottom nut.

3, electric flower sprayer out of the fog-performing, easy drip. This is because the spray nozzle clogging, the filter casing valve is blocked or out of the water contamination caused by other reasons put live. Should clear the nozzle to remove debris; open the casing if the casing should be cleaned clogged strainer, check valve, remove dirt.